Installation Instruction
23.1.07
Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter D: Installation Instruction Page 71
D.7.1 Connection of the 12V starter battery
The positive (+) battery cable is connected
direcly to the solenoid switch of the starter.
Fig. D.26: Connection of positive starter battery cable
The negative (-) battery cable is connec-
ted to the engine foot.
Fig. D.27: Connection of negative starter battery cable
All Panda generators are equipped with an
independent 12V-DC starter motor. The
connecting lines cross-section from the
battery to the DC system should measure
25mm².
1. Solenoid switch for starter motor
2. Starter motor
Fig. D.28: Starter motor
1