A.5 Operation of the generator with automatic start
If the generator set were set up far away from the location of the remote control panel that the
user cannot hear surely, whether the generator starts, a automatic starting option (accessories)
should be installed. With this option the starter is disengaged automatically, if the starting speed
is exceeded.
A.6 Operation of the generator with installation under the
waterline
If the generator cannot be installed clearly at least 600mm over the waterline, a vent valve must
be installed into the raw water line. At installation beside the "midship´s line" a possible heeling
must be considered!
The water hose in the sound cover is split on the pressure side of the pump and extended in each
case in the sound cover at both ends with a connecting nipple by a hose end. Both hose ends
must led out from the sound cover to a point, which is at least for 600mm over the waterline (if
possible in the midship´s line). The valve is inserted at the highest place, at least 600mm over the
waterline.
Cut the hose rubber for the external valve vent.....
Fig. A.14: Connection external vent valve
...and bent it upwards.
Both hose ends must be led out outside of
the sound cover to one point, if possible
600mm over the waterline in the midship
line. The valve is connected at the highest
place with the two hose ends.
Fig. A.15: Connection external vent valve