Maintenance Instructions
Page 28 Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter B: Maintenance Instructions
23.1.07
Pull to the impeller with a multigrip pliers of
the wave.
Mark the impeller, to make sure that these
is used in the correct position at re-instal-
lation.
Fig. B-30: Impeller pump
Check to the impeller for damage and
replace it if necessary.
Before the reinsertion into the housing the
impeller should have been lubricated with
glycerin or with a non-mineral oil based
lubricant e.g. silicone spray.
Fig. B.31: Impeller
The impeller is attached to the pump wave
(if the old impeller is used, pay attention to
the before attached marking).
Fastening the cover and use a new seal.
Fig. B.32: Gasket