Generator Failure
23.1.07
Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter C: Generator Failure Page 39
C.3 Adjusting Instructions for the Spindle of the actuator
Two independent devices limit engine speed range. They are:
a.Regulating nuts on the spindle of the actuator left and right of the spindle nut.
b.An adjusting screw at the base of the rev regulator lever. (only upper revs limit)
1. Actuator
2. Spiral thread spindle
3. Regulating nuts for max. speed
4. Spindle nut with speed regulator level
5. Regulating nuts for min. speed
Fig. C.1: Actuator
During any work on the generator all load
must be switched off to avoid damage to
the equipment. Also the solid state relay,
located in the electrical cabinet should be
disconnected to avoid an accidental
discharge of the booster capacitors.
1. Solid state relay for booster capacitors
2. Solid state relay for booster capacitors
Fig. C.2: Solide state relays 120V/60Hz
1
2
3
4
5
1
2