Installation Instruction
Page 56 Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter D: Installation Instruction
23.1.07
1. Raw water filter
2. Water cock
3. Hull inlet
Make certain that the raw water
filter lies above the water level,
otherwise with cleaning water
can penetrate by the hull inlet.
An external pre-pump can
relieve the impeller.
Fig. D.4: Raw water filter
D.3.4 Installation below waterline
If the generator can not be attached at least 600mm over the
waterline, a vent valve must be installed into the raw water
line. With location beside the "midship line" a possible hee-
ling must be considered! The water hose for the external vent
valve at the back of the sound cover splits on the pressure
side of the pump and at both ends in each case extended
with a connecting nipple by a hose end. Both hose ends must
be led out outside of the sound cover to one point, if possible
600mm over the waterlinee in the midship line. The valve is
connected at the highest place with the two hose ends. If the
valve is blocked, the cooling water pipe cannot be ventilated
after the stop of the generator, the water column is not inter-
rupted and the water can penetrate into the combustion chamber of the engine. This leads to the
destruction of the engine!
Fig. D.5: Vent valve
Cut the hose for the external vent valve...
Fig. D.6: Vent valve
1
3
2