Installation Instruction
Page 68 Panda_12mini_PMS_Digital_s00865_Installation manual.V02 - Chapter D: Installation Instruction
23.1.07
Fig. D.22: Fuel system installation
D.6.2 The electrical fuel pump
Electrical fuel pump
With the Panda generator is usually supp-
lied an external, electrical fuel pump (12V
DC). The fuel pump must be installed close
at the fuel tank. The electrical connections
are preloaded at the generator with the
lead planned.
Fig. D.23: Electrical fuel pump
• Suction hight of the pump: max. 1,2m at 0,2 bar
• Diameter of fuel lines: Table 2, “Diameter of conduits,” on page V.
1
2
3
4
5
6
7
8
1. Generator
2. Fuel stopcock
3. Fuel filter
4. Fuel return
5. Condensation water suction pump
6. Fuel tank
7. Fuel supply
8. Electrical fuel pump (12V-DC)