Maintenance Instructions
Page 76 AGT 6000 PVMV-N 12V_24V - Chapter C: Maintenance Instructions
Loose the attachment screw at the clam-
ping device of the DC-alternator.
Fig. C.6-1: Alternator 12V
Loose the attachment screrw below the
DC-alternator
Press the alternator to the direction of the
thermostat housing.
Now the v-belt can be changed (type:
Gates XPZ 850).
Stretch the v-belt by pulling the return pul-
ley back.
Fig. C.6-2: Alternator 12V
The drive belt should be able to be pres-
sed approx. 10mm with the thumb.
Tighten the fixing screws above and below
the return pulley.
Fig. C.1: V-Belt
For all maintenance and service requirements see the checklist in the „Installation Inspec-
tions“.