Maintenance Instructions
AGT 6000 PVMV-N 12V_24V - Chapter C: Maintenance Instructions Page 67
C. Maintenance Instructions
C.1 Maitenance Requirements
Control before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt, cable connections, hose clips, air
filter
Once a month
• Lubrication of actuator-trapezoid thread spindle
For Maintenance Intervalls see “Maintenance Intervalls” on page 91.
C.2 Oil Circuit Maintenance
The laid down intervals must be heeded in order to avoid serious damage to the motor!
The first oil change should be carried out 35 hours after running time. Thereafter every 100 hours.
SAE 30 is to be used for temperatures over 20°C and SEA 20 for temperatures between 5°C and
20°C. Viscosity SAE 10W or 10W-30 is laid down for temperatures below 5°C.
Required oil:
See Table E.2, “Operating Resources,” on Page 92 and Table E.4, “Technical Data Engine,” on
Page 99
An oil drainage hose is fitted in the sound
cover for changing the oil. This is fed
through the capsule to the outside.
Fig. C.2-1: Oil drainage hose
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...