Remote Control Panda 6-50
Seite/Page 126 - Kapitel/Chapter A: Remote Control Panda 6-50
F1WT1-95E730 Panda 6-50 Fernbedienpanel_eng.fm
Fischer Panda Datasheet
A.3.10 The speed sensor
Speed sensor mounting hole example Panda 8000
Fig. A.3.10-1: Speed sensor
Installation of the speed sensor
The speed sensor tip must have between 0.3 to 0.8mm of clearance (air gap) from the gear tooth tips. In order to
achieve this clearance: the speed sensor tip should be aligned with the tip of a gear tooth and screwed in until it
touches the tip of the tooth. (ATTENTION! Ensure that when inserting the sensor that the sensor tip is not
screwed into the root of the gear tooth). The screw is subsequently turned anticlockwise by half a turn (0.3 to
0.8mm) and held by a counter nut.
1. Speed sensor on threaded seat
2. Engine Flywheel (with gear teeth)
3. Generator housing
4. Retention/tightening nut
ATTENTION! For Panda 8000 and Panda 9000 the speed sensor
has to be mounted in axial direction.
1. Speed sensor on threaded seat
2. Engine Flywheel (with gear teeth)
ATTENTION! For Panda 8000 and Panda 9000 the speed
sensor has to be mounted in axial direction.
Fig. A.3.10-2: Speed sensor
2
3
1
4
1
1
2
2
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...