Remote Control Panda 6-50
F1WT1-95E730 Panda 6-50 Fernbedienpanel_eng.fm
Kapitel/ChapterA: Remote Control Panda 6-50 - Seite/Page 123
Fischer Panda Datasheet
A.3.6
Installation of the Remote Control Panel
As standard, a 12 core connection-cable, 7m long, is
included on delivery. Cores are numbered from 1 to 11
and the 12th core is coloured (yellow/green). The control
cables are securely connected to the genset. On the
back of the control panel there are terminals numbered
from 1 - 12. Connect the cores of the control-cable in
respective order.
Please ensure that the remote control panel is installed in
a protected, dry and easily accessible place.
1. Connector number
2. Cable number
Fig. A.3.6-1: Remote control panel - back side
A.3.7
Fuse on control panel board
It is possible, that the fuse on the control panel board is
defective. Change the fuse if it is defective.
1. Fuse on the control panel board (630 mA, slow to blow)
Fig. A.3.7-1: Remote control panel - back side
A.3.8
Installation assembly kit automatic start - optional - F1WT5-95702
An automatic feature can be supplied as an accessory for all Panda generators (Panda 8000 upwards). This
automatic feature consists of an additional board which can be installed into the back of the remote panel with
little problem. By installing this component the generator is started by means of a single contact (closer), i.e. pre-
warming and starting are carried out automatically.
The normal switch functions of the remote control panel are thereby fully maintained. For example, it is possible to
start the generator by using a time switch, thermo-switch or similar remote instrument. The generator switches on
again after the contact has opened. A starter safeguard lock is absolutely necessary for operating the automatic
feature. This can either be an integral part, or the complete component can be ordered from Fischer Panda
GmbH.
1
2
1
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...