Maintenance Instructions
Page 74 AGT 6000 PVMV-N 12V_24V - Chapter C: Maintenance Instructions
Repeat this process several times.
The generator can be started for 5 minutes, if there is no change in coolant level. Bleeding must
be then repeated two or three times.
It makes sence to repeat the process of ventilation after a couple of days to ensure that even-
tually remaining bubbles be removed out from the system
If the radiator should be vertically installed, or even under the vehicle floor, so that an external
balance container is used, filling up may only happen over this balance container, and not over
the radiator.
Now the cooling water is only filled over the
external expansion tank.
This is connected by a hose with the gen-
set. The external expansion tank should be
filled in the cold condition only up to maxi-
mally 20%. It is very important that a large
extension space over the cooling water level
remains.
Fig. C.4-6: External expansion tank
C.5 Exchange the air filter
Open the closure at the housing front side.
Fig. C.5-1: Air filter