VCS-AGT-U/I
Page 102 - Chapter A: VCS-AGT-U/I
VCS-AGT-UI_eng.fm
Fischer Panda Datasheet
The poti next to clamp 7/8 is needed for adustment of the mesurement voltage and should be done by an service
technican only
The poti next to clamp 9/10 is needed for adustment of the mesurement current and should be done by an service
technican only
The VCS control is used for the adjustment of the number of revolutions of the engine and thus the voltage of the
generator. It belongs to the accessories and is externally attached.
Nr.
Kurzbezeichnung
E/A
Benennung / Funktionsbeschreibung
1
+ Actuaror
A
Out (+) for actuator
2
- Actuator
A
Out (-) for actuator
3
+12V
E
Operation v); 12V-Automotive
4
0V
E
Operation voltage(-); 12V-Automotive
5
AC Controllamp
A
to 0V - Optional
6
VCS on
E
12V: VCS is on / open : VCS is off
7
Mesurement v
E
Mesurement voltage (+) from the generator
8
Mesurement voltage -
E
Mesurement voltage (-) from the generator
9
Mesurement c
E
Mesurement current (+) from the generator
10
Mesurement current -
E
Mesurement voltage (-) from the generator
Fig. A.2-1: Clamps of the VCS
A.2.1 Gerneral working of the VCS
Whem the VCS is activ (+12V on clamp 6) the VCS controls the actuator to reach the exact voltage.
The mesurement voltage is taken from the generator by an shunt which has 60mV nominal.
1
2
1. Clamp 9/10
2. Potentiometer for the Current
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...