Battery monitor in DIN-tracks housing (RE9517)
Seite/Page 106 - Kapitel/Chapter A: Battery monitor in DIN-tracks housing (RE9517)
Anleitung_RE9517_eng.fm
Fischer Panda Datenblatt/Datasheet
Automatic monitoring of a battery voltage. If the adjusted threshold for battery undervoltage is fallen below, then (e.g.
over the AGT panel RE9513) a battery charge generator is started. If the adjusted threshold for charge voltage is
crossed, then the generator - at expiration of an adjustable deceleration time - is stopped.
Battery undervoltage, charge voltage and delay time can be stopped over potentiometers. If battery undervoltage
was recognized, this is indicated over an LED. Threshold excesses and falling below must line up min. 40s, so that a
shifting process can be released. The battery monitor supplies itself from the battery which can be supervised. The
exit is electrically isolated by an opto coupler from this electric circuit. As output logic element the output transistor of
the optocoupler is used. Thus the output signal is polarized and the exit must be attached correctly. A wrong polarity
of the exit can lead to the destruction of the battery guard, as well as attached devices!
The battery monitor is setup for a definied voltage. (i.e. 24V or 36V). It is not possible to change these voltage.
• charging rate : max 7mADC
• output (clamp 7 = positive [+], clamp 8 = negative [-])
• max operation voltage: 35VDC
• max backward voltage: -4VDC
• max operation current: 10mADC
• output is electrically isolated from the measuring input
• setting ranges:
• charge conclusion voltage: 2.25V - 2.42V per cell
• battery base voltage: 1.83V - 2.04V per cell
• tolerance of the range limits: ± 2,5%
• tolerance of the operation points: ± 1%
A.2 Brief description
A.3 Function
A.4 Technical data and settings
Art. No.
Art. Name
Nominal
Voltage
Mesuring Voltage
cont./short time
) Clamp2(-)
F1RORE9517-012
Batterymonitor typ RE9517 12V-DC
12 Volt
25 V DC / 27V DC
F1RORE9517-024
Batterymonitor typ RE9517 24V-DC
24 Volt
32 V DC / 35 V DC
F1RORE9517-036
Batterymonitor typ RE9517 36V-DC
36 Volt
56 V DC / 60 V DC
F1RORE9517-048
Batterymonitor typ RE9517 48V-DC
48 Volt
86 V DC / 95 V DC
F1RORE9517-072
Batterymonitor typ RE9517 72V-DC
72 Volt
110 V DC / 120 V DC
F1RORE9517-080
Batterymonitor typ RE9517 80V-DC
80 Volt
F1RORE9517-120
Batterymonitor typ RE9517 120V-DC
120 Volt
F1RORE9517-144
Batterymonitor typ RE9517 144V-DC
144 Volt
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...