CAUTION!
The AGT-generator is not allowed to be
connected to an inverter (without batteries)!
The Inverter generates voltage peaks, which can destroy the rectifier rectifiers of the generator!
A battery must always be connected to the inverter as a capacity!
Recommended capacity at
12V
≥
240Ah at 24V
≥
120Ah
The screws at the electric rectifier may be pulled tight only with a torque wrench. Torque 6 Nm.
The battery cable must be secured at the generator and at the batteries with appropriate safety devices.
The generator is also include into the CO
2
- fire-extinguishing system.