Appendix
Page 92 AGT 6000 PVMV-N 12V_24V - Chapter E: Appendix
*) or every 12 month
Temperature switch / watertemperature IN/OUT,
at full load and max. speed of cooler, bridged
temperature sensor / temperature switch
X
X
X
X
X
X
X
X
X
X
X
Actuate all ventilation valves -screws
X
X
X
X
X
X
X
X
X
X
X
With actuate the failure bypass switch check if
the waterpump works faultless (only at gents wit-
hout v-belt drived waterpump)
X
X
X
X
X
X
X
X
X
X
X
Check v-belt
X
X
X
X
X
X
X
X
X
X
X
Pressure test the injection nozzel (every 2000 h)
The motor manufacturer’s regulations and instructions must be observed, especially operating and inspection
instructions ! (See the motor manufacturer’s operating instructions.)
E.2
Operating Resources
E.2.1 Engine oil
Engine oil classification
Operating range:
The operating range of an engine oil is determined by SAE class. " SAE " is for the union of American engineers
(Society of Automotives Engineers).
The SAE class of an engine oil only informs over the viscosity of the oil (larger number = more viscous, lower
number = more highly liquidly) e.g. to 0W, 10W, 15W, 20, 30, 40. The first number shows the liquid of cold wea-
ther, the second number refers to the fluidity with heat. Complete yearly oils have usually SAE 10W-40, SAE
15W-40 etc.
Quality of oil:
The quality of an engine oil is specified by the API standard ("American Petroleum Institutes").
The API designation is to be found on each engine oil bundle. The first letter is always a C.
API C for diesel engines
The second letter is for the quality of the oil. The more highly the letter in the alphabet, the better the C für Diesel-
motoren.
Examples for diesel engine oil:
API CC Engine oil for small demands
API CG Engine oil for highest demands, turbo-tested
Fischer Panda recommend the API-class CF !
After operating hours:
3
5
-5
0
h
1
0
0
h
2
0
0
h
3
0
0
h
4
0
0
h
5
0
0
h
6
0
0
h
7
0
0
h
8
0
0
h
9
0
0
h
1
0
0
0
h
Содержание AGT 6000 PVMV-N
Страница 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Страница 6: ......
Страница 10: ...8 Socket wrench set Hexagon wrench keys ...
Страница 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Страница 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Страница 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Страница 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...