Farmer 400
Fav 700
Fav 900
Electrics / system in general
A004 - control console
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001; 900 > 23/3001;
6.3.2001
9000
000092
E
a
1/4
Capitel
Docu-No.
Index
Date
Version
Page
A004 - control console
Single e-box
PM-Picturemodule
Text-module
Checking power supply to A004 - control console
Note:
Ignition "ON".
Text-module
Text-module
Pin assignment and signal values
Note:
Ignition "ON"
Connect e-adapter box X 899.980.208.100 directly to A004 - control console.
All re/- 10%
Description of control console signal type, see Chapter 9700 Index A
Text-module
PMTAB_Picture
Connect e-adapter box X 899.980.208.100
directly to A004 - control console.
Test
Pin
Target value Condition
Possible cause of fault
+UB15 supply
28
12 VDC
to 14 VDC
Fuse (F044) in X051 or in wiring
Sensor system
earth
1
+UB30 supply
54
12 VDC
to 14 VDC
Fuse (F042) in X051 or in wiring
Sensor system
earth
1
+UB30 supply
56,57,5-
8,59,60
12 VDC
to 14 VDC
Fuse (F042) in X051 or in wiring,
X604 connector UB30
Sensor system
earth 1
1
Pin
Pin description
Signal type
Signal at component
Signal from
A004 (break
in cable)
1
Analogue earth
2
Not assigned
3
Not assigned
4
Not assigned