Farmer 400
Fav 700
Fav 900
Electrics / system in general
Y014 - "Raise" suspension solenoid valve
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001, 900 > 23/3001
01/2000
9000
000122
E
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
Y014 - "Raise" suspension solenoid valve
Single e-box
Instructions for applied-voltage test on valves, if required:
ETNum-list
1. Disconnect existing actuation lead (open toggle switch or remove bridge on adapter box).
2. Connect separate voltage source to component contact.
3. Separate voltage source: pins 56, 57 ... or 60 on e-box A002 or battery/power supply unit