Fav 900
Engine / Injection System
Injection Pump - Auxilliary Operation
A
General
Fav 900 Chassis Number 23/3001 and up
06.11.2000
2710
000003
A
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
Injection Pump - Auxilliary Operation
Text-module
Auxilliary Operation Of EDC Injection Pump VP 44 (A020)
Injection Pump can be used in auxilliary operation if the electronic control becomes impossible due to
Failure Codes.
PM-Picturemodule
Text-module
PM-Picturemodule
PMTAB_Picture
Injection Pump A020 on:
Pin 7 (B) and on
Supply externally 12 VDC with Adapting
Connector on Pin 6 (Battery -) .
Pin attribution on Pump Control module
Pin
Wire.-Nr./ Colour
Attribution
1
white / green
CAN Low
2
green
CAN High
3
--
not attributed
4
--
not attributed
5
60303
Engine Stop via Solenoid Valve
6
31000 / white / red
Earth
7
60017 / red
+ U Battery
8
60357
Speed Input Signal
9
--
not attributed
PMTAB_Picture
Adapting Connector X 899.980.251.101
Connect Compact Conector with Injection pump.
Connect Insertion Cable with:
+ UB Contakt (red) with Cable Nr. 7
Earth Contact (black) with Cable Nr. 6