Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
17/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
4.1.A4 A009
Transmission control
unit
Fault or logical error in
ECU signal.
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.A5 A009
Transmission control
unit
Initial -Reference (=Zero
position) could not be
reached during ignition
"ON"
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.A6 A009
Transmission control
unit
Reference point signal
fault during operation
Continuation in
emergency mode
possible
TRANSMISSION,
TRANSMISSION
CONTROL
4.1.B0 all bus
consu-
mers
Initialisation error
Restricted CAN-bus
data communication
4.1.B1 Y001
Y002
Speed range control
Illogical speed range
operation (=fatal error)
Continuation in
emergency mode
possible
4.1.B2 A002
ECU, enhanced control Fault in EPROM
programming (range
control I / II)
Range cannot be
changed while driving.
EOL reprogramming
necessary
4.1.B3 A002
ECU, enhanced control Fault in EPROM
programming (rapid
reversing ramp
parameters)
Rapid reversing
posssible with standard
values.
EOL reprogramming
necessary
4.1.B4 B010
Sensor, engine 1
Input parameter values
for plausibility
monitoring are incorrect.
Standard parameters
are stored, plausibility
monitoring system
remains functional.
EOL reprogramming
necessary
4.1.E0 Y004
Turboclutch caracteristic Wrong caracteristic
stored
Continuation in
emergency mode
possible
EOL reprogramming
necessary
4.1.E9
Values for shift from
range II to I outside
tolerances
Shifting only possible
when stationary
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note