Fav 900
Electrics / General system
Y012 - "Charge" suspension solenoid valve
E
Testing
Fav 900 chassis number 23/3001 and up
04.09.2001
9000
000153
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
Y012 - "Charge" suspension solenoid valve
Text-module
Note:
Ignition "OFF"
Connect adapter cable X 899.980.246.201 directly to Y012 - "Charge" suspension solenoid valve.
Note:
Ignition "ON"
PM-Picturemodule
Pin
Function
1
12 volt actuation
2
Vehicle earth
Test
Pin
Target value Condition
Remark
Signal
1
8 ohms
Earth
2
Test
Pin
Target value Condition
Possible cause of fault
Signal
1
12 VDC
Suspension: raise or lo-
wer or oil preheater
(=flush)
Fuse F050 in X051 or in wi-
ring
Earth
2
Actuation via K016 - sus-
pension valves relay
PMTAB_Picture
Connect e-adapter box 899.980.208.100 to cable
coupler X043 using
adapter cable X 899.980.208.205.