Farmer 400
Fav 700
Fav 900
Hydraulic systems / external pressure supply
Fitting instructions for external pressure supply
G
Repair
Fitting instructions
24.08.2001
9666
000001
G
a
6/6
Capitel
Docu-No.
Index
Date
Version
Page
Fitting instructions for external pressure supply
PM-Picturemodule
Text-module
Note:
For a detailed description of the LS pressure increase please refer to the Favorit 900 workshop
manual, chapter 9666 A 00001.
PM-Picturemodule
PM-Picturemodule
LS pressure increase
PMTAB_Picture
PMTAB_Picture
●
Screw on 2-way ball valve (40).
1x support
2x M8x12 8.8 hexagon bolt
2x spring washer
1x shackle
2x M6x40 8.8 hexagon bolt
2x M6 hexagon bolt
2x spring washer
●
Screw on pressure pipes (30, 42).
PMTAB_Picture
●
Unscrew existing pressure pipe (37).
●
Screw on L-coupling (43).
●
Screw supplied pressure pipe and pressure pipe
from 2-way ball valve (42) to L-coupling.