Farmer 400
Fav 700
Fav 900
Electrics / system in general
S015 - handbrake switch
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001; 900 > 23/3001
03/2000
9000
000037
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
S015 - handbrake switch
Single e-box
Text-module
Note:
Connect adapter cable X 899.980.246.206 directly to component S015.
Ignition "ON".
Text-module
Text-module
Note:
Checking A004 - control console, Chapter 9000 Index E
Pin
Function
1
Not assigned
2
Not assigned
3
Signal
4
Earth
Test
Pin
Target va-
lue
Condition
Possible cause of fault
Signal
3
2.4 VDC
Handbrake off
5.1 VDC
Handbrake on
Earth
4
Measuring points on A004 - control console
Pin
Earth
1
Signal
18