![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870357.webp)
Fav 900
Transmission / Vario transmission unit
Fitting continuously variable transmission
G
Repair
Fav 900 chassis number 23/3001 and up
16.05.2001
1080
000007
G
a
5/9
Capitel
Docu-No.
Index
Date
Version
Page
Fitting continuously variable transmission
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Fit hydraulic hose (pressure supply to enhanced
shift system).
PMTAB_Picture
Insert pressure hoses into bores on right in
transmission housing.
1 = pressure supply hydraulic hose (enhanced
pressure)
2 = range control I
3 = mechanical speed governor
4 = range control II
5 = control valves (adjustment)
6 = high pressure to clutch and turboclutch
operation (steel line)
PMTAB_Picture
Secure pressure hoses using circlips.
PMTAB_Picture
Screw two M8 stud bolts into transmission
housing.
Fit new gasket, stick new O-rings into valve unit
using a little grease.
Insert valve unit and tighten fastening screws to
25 Nm (from inner to outer)