Installation
Overview
This section provides an overview of the installation process. To set up the VNE 250 and
VND 250, follow these instructions and the instructions referenced by the links provided:
1.
If required, install small form-factor pluggable (SFP) connectors in the LAN 2 ports (see
on page 17).
2.
Select a suitable location and mount the VNM 250 devices (see
page 130). Depending on your system, there may be multiple locations and multiple
units at each location.
3.
on the VNM 250 devices by connecting the provided power supplies (see
page 14). Do not connect the devices to a network.
4.
Decide which device is the system controller. For large systems (more than 10 devices),
you must use a VN-Matrix Enterprise Controller. To configure the system using the
Enterprise Controller, see the
VN-Matrix Enterprise Controller User Guide
.
For smaller systems, you can use the Enterprise Controller or a VNM 250 unit as the
controller (see
Low Level Device Configuration
on page 25).
5.
Connect the Control connector of the rear panel Coms port (three poles of the 5-pole
captive screw connector) to a control computer. Use DataViewer to configure the IP
addresses for both the control port and streaming port, the subnet mask, and gateway
for each unit (see
Low Level Device Configuration
ATTENTION:
•
Prepare thoroughly before connecting or configuring the VNM 250 for an
existing network. Contact your network administrator to ensure you have the
correct network information for each device that is being added to the network.
Incorrect connection or configuration may disrupt the network.
•
Préparez minutieusement avant toute connexion ou configuration le VNM 250
pour un réseau existant. Contactez votre administrateur réseau pour vous
assurer que vous détenez les bonnes informations relatives au réseau pour
chaque appareil relié au réseau. Une connexion ou configuration incorrecte est
susceptible de perturber le réseau.
NOTE:
Extron recommends configuring the IP addresses through the Coms port
on the rear panel. Alternatively, it is possible to use SIS commands (through the
USB port on the front panel) or the front panel menu.
VNM 250 • Installation Overview