Commissioning
Prosonic S FMU95
62
E Hauser
"customer unit"
Use this parameter to select the desired unit for the linearized values (e.g. kg, m
3
, ft
3
, ...). This unit
is only indicated on the display. It does not cause a conversion of the measured value.
!
Note!
After selecting the option "customer specific", the parameter "customized text" appears. An arbitrary
string (consisting of up to 5 alphanumeric characters) can be entered into this parameter.
"maximum scale"
Use this parameter to specify the maximum content of the vessel in the customer unit.
"diameter"
Use this parameter to specify the diamter of the horizontal cylinder or the spherical tank
respecitvely.
"intermediate height"
Use this parameter to specify the intermediate height of the vessel.
"mode"
L00-FMU90xxx-19-00-00-yy-015
Use this parameter to specify if the measurement
refers to the
"level"
(A) or to the
"ullage"
(B).
100%
20
mA
0%
0/4
mA
A
B