Prosonic S FMU95
Commissioning
E Hauser
57
"LVL N full calibration" (N = 1 - 10)
"full F"
"blocking distance"
Indicates the blocking distance of the respective sensor. The blocking distance is measured from the
sensor membrane (reference point of the measurement).
LVL1 full calib.
L1006
full F:
0,00 m
block.dist. BD:
L00-FMU90xxx-19-00-00-yy-008
Use this parameter to specify the span F, i.e. the distance from the
minimum level to the maximum level.
– Default setting: depending on sensor type
– Range of values: depending on sensor type
– blocking distance BD: depending on sensor type (see table)
"
Caution!
The maximum level may not project into the blocking distance:
F
max
= E - BD
20mA
100%
0/4mA
0%
BD
F
E
Type of sensor
Blocking distance (BD)
Maximum measuring distance
1)
1)
valid for optimum process conditions
FDU90
0.07 (0.2)
3.0 (9.8) (for liquids)
FDU91/FDU91F
0.3 (1.0)
10 (33) (for liquids)
FDU92
0.4 (1.3)
20 (66) (for liquids)
FDU93
0.6 (2.0)
25 (82) (for liquids)
FDU95 - *1*** (low temperature version)
0.7 (2.3)
45 (148) (for solids)
FDU95 - *2*** (high temperature version)
0.9 (3.0)
45 (148) (for solids)
FDU96
1.6 (5.2)
70 (230) (for solids)
FDU80/FDU80F
0.3 (1.0)
5 (16) (for liquids)
FDU81/81F
0.5 (1.6)
10 (33) (for liquids)
FDU82
0.8 (2.6)
20 (66) (for liquids)
FDU83
1.0 (3.3)
25 (82) (for liquids)
FDU84
0.8 (2.6)
25 (82) (for solids)
FDU85
0.8 (2.6)
45 (148) (for solids)
FDU86
1.6 (5.2)
70 (230) (for solids)
m (ft)
Содержание Prosonic S FMU95
Страница 2: ......
Страница 104: ...Appendix Prosonic S FMU95 104 Endress Hauser...
Страница 107: ...Prosonic S FMU95 Index Endress Hauser 107...
Страница 108: ...www endress com worldwide BA00344F 00 EN 13 12 71164423 FM SGML 9 0 71164423...