Instruction Manual
IM-106-910C, Rev. 1.0
November 2009
Hazardous Area
X-STREAM O
2
Transmitter
http://www.raihome.com
Section 1
Description and Specifications
Component Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1
System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1
Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1
System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-3
System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-4
System Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-4
Automatic Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-7
Communication Options . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-7
Probe Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-9
Diffusion Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-10
COMPONENT
CHECKLIST
A typical Rosemount Analytical Hazardous Area X-STREAM O
2
Combustion
Flue Gas Transmitter should contain the items shown in Figure 1-1. Record
the part number, serial number, and order number for each component of your
system in the table located on the back cover of this manual.
Also, use the product matrix (Table 1-1) at the end of this section to compare
your order number against your unit. The first part of the matrix defines the
model. The last part defines the various options and features of the
Hazardous Area X-STREAM O
2
Transmitter. Ensure the features and options
specified by your order number are on or included with the unit.
SYSTEM OVERVIEW
Scope
This Instruction Manual is designed to supply details needed to install, start
up, operate, and maintain the Hazardous Area X-STREAM O
2
Transmitter
system. Signal conditioning electronics outputs a 4-20 mA signal representing
an O
2
value. This information, plus additional details, can be accessed with
the handheld HART Model 375 Field Communicator or Asset Management
Solutions (AMS) software. Also, a fully functional Xi Enhanced Interface
(optional) for setup, calibration, diagnostics, and enhanced features is
available.
The Xi Enhanced Interface communicates with the probe transmitter
electronics via HART communications riding on the 4 to 20 mA signal coming
from the transmitter. This communication will be disrupted if a 375 Field
Communicator is connected to this circuit. Connect the field communicator
only to the 4 to 20 mA signal loop between the Xi Enhanced Interface and the
control room or data acquisition system.
Содержание Rosemount X-STREAM O2 Transmitter
Страница 2: ......
Страница 4: ......
Страница 8: ...Hazardous Area X STREAM O2 Transmitter TOC 4 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 10: ...Hazardous Area X STREAM O2 Transmitter ii Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 32: ...Hazardous Area X STREAM O2 Transmitter 1 16 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 58: ...Hazardous Area X STREAM O2 Transmitter 2 26 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 66: ...Hazardous Area X STREAM O2 Transmitter 3 8 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...