Instruction Manual
IM-106-910C, Rev. 1.0
November 2009
6-7
Hazardous Area
X-STREAM O
2
Transmitter
7. Loosen the setscrews in diffuser (6, Figure 6-1). The snubber diffuser is
shown but the ceramic and Hastelloy diffusers are attached similarly.
NOTE
If removing a ceramic or Hastelloy diffuser be sure to note the orientation of
the rounded deflector so the diffuser can be reinstalled the same way.
8. Remove diffuser (6) from sensor core assembly (1). Replace damaged
diffuser or sensor core assembly with a new replacement part.
9. Remove the setscrews from the diffuser. Apply anti-seize compound to
threads of setscrews and thread setscrews three turns into the diffuser.
NOTE
If installing a ceramic or Hastelloy diffuser be sure to orient the rounded
deflector so it points upstream relative to the flue gas air flow.
10. Install diffuser (6) onto sensor core assembly (1) using the same
orientation as noted in step 6. Tighten the diffuser setscrews.
11. Apply a light coating of silicone grease onto the o-ring of sensor core
assembly (1).
12. Install sensor core assembly (1) in probe tube (7).
13. Install and tighten three screws (19) to secure sensor core assembly (1)
inside probe tube (7).
14. Connect the sensor core plug to electronics board (8).
15. Re-connect the cal gas and reference air hoses as shown in Figure 6-3.
The cal gas hose connects between the hose ports marked "C". The
reference air hose connects between the hose ports marked "R".
16. Recalibrate the probe per "O2 Calibration" in "Startup and
Operation"Section 4: Startup and Operation.
Do not use excessive force when installing the reference air or cal gas hose onto the
connecting tube. Using excessive force can buckle the stainless steel tubing.
Failure to correctly install the hoses may allow gas leakage and result in erroneous O
2
readings. Be sure to correctly install the calibration gas and reference air hoses.
Содержание Rosemount X-STREAM O2 Transmitter
Страница 2: ......
Страница 4: ......
Страница 8: ...Hazardous Area X STREAM O2 Transmitter TOC 4 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 10: ...Hazardous Area X STREAM O2 Transmitter ii Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 32: ...Hazardous Area X STREAM O2 Transmitter 1 16 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 58: ...Hazardous Area X STREAM O2 Transmitter 2 26 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...
Страница 66: ...Hazardous Area X STREAM O2 Transmitter 3 8 Instruction Manual IM 106 910C Rev 1 0 November 2009 ...