51
Parameter setting
Actuators KNX S4-B10, KNX S2-B6 and KNX S1-B2 230 V
Status: 18.04.2017 • Technical changes and errors excepted.
Automatic reset:
With the manual operation the automatic of the drive is deactivated. Here it is set when
the automatic is reactivated.
Automatic blocking object:
With the automatic blocking object, the automatic can be deactivated for a short term
(e.g. if present or during speeches in conference rooms).
Here it is also specified in which mode the channel is found when the voltage returns,
i.e. after a power failure. The mode (manual or automatic) is send as a status object to
the bus.
Type of automatic:
The automatic for the connected drive can be specified externally, however all the set-
tings can also be configured internally. If "internal automatic" is chosen, a separate
menu item "Automatic" (see chapter
Movement limits
, page 54 or
Automatic for
windows (drives)
, page 60) appears.
Block – blocking objects
The menu item only appears if a block with blocking object was configured for "cont-
rol". Here it is specified was happens for object value 1 and 0. Via the free blocking ob-
ject, a fire alarm scenario may be configured for example (create escape routes by re-
tracting the shading, smoke extraction via windows). This can prevent being locked out
on the patio (opened window contact of the patio door blocks the shutter in front of the
door).
Manual switches to automatic after
• expiry of a waiting period
• reception of an object
• expiration of a waiting period or receipt of
an object
Waiting period in min
(if "Expiration of a waiting period" was
chosen)
1...255; 20
Switch to automatic for an object value
(if "Receipt of an object" was chosen)
0 • 1 • 0 or 1
Use automatic blocking object
no • yes
Operating mode after power returns
• Automatic
• Manual
Send status object
• 1 for automatic | 0 for manual
• 0 for automatic | 1 for manual
Send delay of the status output
Automatic or Manual in 0.1 sec
0...50
Type of automatic
external automatic • internal automatic