5
!
!
WARNING
WHEN THIS FURNACE IS INSTALLED IN A RESIDENTIAL GARAGE, IT MUST BE INSTALLED
SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18” ABOVE THE
FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH MAY BE PRES-
ENT IN THE GARAGE.
THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY VE-
HICLES.
FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING IN
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FIGURE 1 - FURNACE DIMENSIONS AND CLEARANCE TO COMBUSTIBLES
TABLE A - FURNACE DIMENSIONS
Model Width
A
Depth
B
Height
C
Vent
H
Supply Air
(F x G)
Return Air
(D x E)
60
16⅞”
29”
40”
2”
15⅞ x 20
14 x 22
80
18½”
29”
40”
2”
17½ x 20
14 x 22
100
20½”
29”
40”
2”
19½ x 20
14 x 22
120
23½”
29”
40”
2”
22½ x 20
14 x 22
For downflow installations use optional sub-
base kit 550001346