7 Modbus RTU
7.4 Operating mode Modbus RTU
DE1 variable speed starter
09/14 MN040011EN
www.eaton.com
121
7.4.3 Register mapping
Register mapping makes it possible to process, in DE1 variable speed
starters, the contents in the following table via Modbus RTU.
7.4.3.1 Input process data
The input process data is used to control the DE1 variable speed starter.
Group
ID range
Assignment of the ID numbers
Parameter
129 - 175
List of parameters
Chapter 11 “List of parameters”, page 169
Input process data
1 - 4
Section 7.4.3.1, “Input process data”, page121
Output process data
6 - 24
Section 7.4.3.2, “Output process data”, page123
→
Certain master controllers (e.g., PLCs) may feature an ID offset
of +1 in the interface driver used for Modbus RTU
communications.
→
The decimal point is not taken into account when processing
values!
For example, a DE1 variable speed starter motor current of
0.3 A will be transmitted as 003
dec
on Modbus, while a current
of 2.2 A will be transmitted as 022
dec
.
ID
Designation
Scaling Factor
Unit
1
Field bus command
–
Binary code
2
Field bus speed reference value
0.1
Hz
3
reserved
–
–
4
Modbus ramp time
0.01
s
Содержание PowerXL DE1 series
Страница 4: ...II ...
Страница 36: ...2 Engineering 2 5 Motor Selection 32 DE1 variable speed starter 09 14 MN040011EN www eaton com ...
Страница 68: ...3 Installation 3 6 Block diagrams 64 DE1 variable speed starter 09 14 MN040011EN www eaton com ...
Страница 132: ...7 Modbus RTU 7 4 Operating mode Modbus RTU 128 DE1 variable speed starter 09 14 MN040011EN www eaton com ...
Страница 146: ...8 Technical Data 8 4 Dimensions 142 DE1 variable speed starter 09 14 MN040011EN www eaton com ...
Страница 172: ...10 Fault messages 10 3 Fault list 168 DE1 variable speed starter 09 14 MN040011EN www eaton com ...
Страница 186: ...182 DE1 variable speed starter 09 14 MN040011EN www eaton com ...