A jammed grinder may trip the circuit breaker or cause the overload protector to cycle and this
will cause the pump to cycle on and off and finally result in an alarm condition. A torn or worn
out pump stator results in a “runs but does not pump” condition and causes an alarm. Current
readings with a clamp-on amp meter will show 4.0 to 4.5 amps when the motor is running
without a load. Replace the stator and, if necessary, the rotor.
Amps @
240V (120V)
PSI
Head (ft)
GPM
Comments
4.9 (9.8) or less
0
0
0
Worn stator
5.6 (11.2)
10
24
14
Normal
5.8 (11.6)
20
46
13
Normal
6 (12)
30
70
12
Normal
6.2 (12.4)
40
92
11
Normal
6.5 (13)
50
115
10
Normal
6.8 (13.6)
60
138
9
Normal
7.1 (14.2)
70
161
8
Normal
7.4 (14.8)
80
184
7.5
Normal
8+ (16+)
90+
207+
Varies
Plugged discharge line or bad bearings
>15 (>30)
0
0
0
Jammed grinder or shorted motor
Table 12–1
Amperage Draw Readings
Содержание Extreme Series
Страница 1: ...Service Manual E One Extreme Grinder Pumps 240V 60 Hz Hardwired Controls...
Страница 2: ......
Страница 32: ...Pump End 5 8 Figure 5 9a D Series Pump Exploded View...
Страница 33: ...Pump End 5 9 Figure 5 9b W Series Pump Exploded View...
Страница 34: ...Pump End 5 10 Figure 5 9c Gatorgrinder GH Series Pump Exploded View...
Страница 35: ...Pump End 5 11 Figure 5 9d IH091 Pump Exploded View...
Страница 36: ...Pump End 5 12...
Страница 58: ...Level Sensor 8 10 Figure 8 35 Level Sensor Assembly Exploded View all hardwired pumps...
Страница 70: ...Mechanical Seal Assembly 11 2...
Страница 75: ......