Troubleshooting 2–6
Color/Pin #
Color/Pin #
Normal Reading
Operation
If Reading is Wrong, Check:
Brown 1
Red 2
OL or Open
On/off switch off
Bad switch; wet EQD; miswired;
plugged sensing line; obstructed vent;
restricted breather tube
Yellow 5
Blue 6
OL or Open
Alarm switch off
Bad switch; wet EQD; miswired;
plugged sensing line; obstructed vent;
restricted breather tube
Green 4
Black 3
0.00 — Short
Neutral
Neutral not connected
Green 4
Red 2
Yellow 5
OL or Open
No shorts to
ground
Supply cable cut; water in EQD or
pump controls. Unplug EQD and
retest to isolate shorts.
Green 4
Blue 6
0.1
(200K scale)
Ground to Neutral
feedback across
alarm relay coil
Verify Neutral is good on alarm board;
possible bad bulb or relay on board.
Jump Yellow to Blue to check relay
(pump, buzzer and light should come
on).
Brown 1
Blue 6
0.5
(200K scale)
Redundant run to
alarm return
Supply cable cut; water in EQD or
pump controls. Unplug EQD and
retest to isolate the shorts.
Brown 1
Yellow 5
OL or Open
(200K scale)
Redundant run to
alarm send
Cut cable; wet EQD or controls; stuck
manual run switch
Brown 1
Black 3
Green 4
.400
(200K scale)
Contactor coil
Bad coil; wet controls
120V Continuity Checks
This table assumes the pump has shut off on its own or is not installed in a tank.
Table 2–5
This table assumes enough water is in the tank to turn on the alarm.
Color/Pin #
Color/Pin #
Normal Reading
Operation
If Reading is Wrong, Check:
Brown 1
Red 2
0.00 — Short or
closed circuit
On/off switch on
Low water level; wet EQD; EQD un-
plugged; broken wire; miswired; bad
switch; sensing line leak or blockage;
blocked vent; restricted breather tube
Yellow 5
Blue 6
0.00 — Short or
closed circuit
Alarm switch on
Bad switch; wet EQD; miswired;
plugged sensing line; obstructed vent;
restricted breather tube
Green 4
Black 3
0.00 — Short
Neutral
Neutral not connected
Green 4
Red 2
OL or Open
No shorts to
ground
Supply cable cut; water in EQD or
pump controls. Unplug EQD and
retest to isolate the shorts.
Green 4
Yellow 5
Blue 6
0.1
(200K scale)
Ground to Neutral
feedback across
alarm relay coil
Verify neutral is good on alarm board;
bad bulb; possible bad relay on
board. Jump Yellow to Blue to check
relay (buzzer and light should come
on).
Brown 1
Yellow 5
Blue 6
0.5
(200K scale)
Redundant run to
alarm
Supply cable cut; water in EQD or
pump controls. Unplug EQD and
retest to isolate the shorts.
Brown 1
Black 3
Green 4
.400
(200K scale)
Contactor coil
Bad coil; wet controls
Table 2–6
Содержание Extreme Series
Страница 1: ...Service Manual E One Extreme Grinder Pumps 240V 60 Hz Hardwired Controls...
Страница 2: ......
Страница 32: ...Pump End 5 8 Figure 5 9a D Series Pump Exploded View...
Страница 33: ...Pump End 5 9 Figure 5 9b W Series Pump Exploded View...
Страница 34: ...Pump End 5 10 Figure 5 9c Gatorgrinder GH Series Pump Exploded View...
Страница 35: ...Pump End 5 11 Figure 5 9d IH091 Pump Exploded View...
Страница 36: ...Pump End 5 12...
Страница 58: ...Level Sensor 8 10 Figure 8 35 Level Sensor Assembly Exploded View all hardwired pumps...
Страница 70: ...Mechanical Seal Assembly 11 2...
Страница 75: ......