Level Sensor 8–3
2.
Using needlenose pliers, remove the pressure switch retainers from both sides of
level sensor (Fig. 8-6). Remove the flag terminals from the switches (Fig. 8-7).
3.
Remove the on/off switch (Fig. 8-8) and the molded radial seal (Fig. 8-9).
Note:
The
seal will also stick in the alarm side.
4.
Clip the flag terminals from the wires, loosen the cord grip compression nut and pull
out the cable (Fig. 8-10). Remove the alarm switch (Fig. 8-11).
Figure 8-6
Figure 8-7
Figure 8-8
Figure 8-9
Figure 8-10
Figure 8-11