background image

READ ALL INSTRUCTIONS AND INSTALLATION INSTRUC-
TIONS THOROUGHLY. FAILURE TO FOLLOW THE INSTRUC-
TIONS COULD RESULT IN SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.

CAUTION:

Check to be sure power source is adequate for handling

the voltage requirements of the pump, as indicated on the pump
nameplate.

Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers for proper capacity. A separate branch
circuit is recommended, sized according to NEC code for current
shown on the pump nameplate.

Pump should be checked frequently for debris and/or build up
which may interfere with the floats on and off position. 

A check valve is to be used to reduce unnecessary cycling of pump.

This pump is not intended (designed) to be used for handling raw
sewage.

SAFETY GUIDELINES

INSPECTION

Inspect unit for any visible damage caused by shipping. Contact
dealer if unit appears to be damaged.

INSTALLATION INSTRUCTIONS

Read all instructions before beginning installation.

Be sure the installation does not exceed the maximum vertical lift
(head) of 20 ft.

Use backfill gravel that is larger than the holes in the basin. Not
doing so will cause damage to the pump which will void the warranty.

Select an area that collects water, typically near the foundation,
and dig a hole approximately 1 ft. larger in diameter and deep enough
to allow the tank lid to be about 2" above the ground.

Make sure the basin is level to within 1/8" across the diameter.

Install check valve to pump, hand tight is sufficient. Snap in the 2"
grommet in the cover. Thread hose through the 2" grommet and
connect hose to check valve using hose clamp provided. Feed the
pump power cord through the other hole in the cover. Feed the
discharge hose out away from the house (see illustration).

To test, plug the pump in and run water into the basin until the
pump switches on. If the pump does not switch on refer to trouble
shooting information in the instruction sheet for the pump.

Secure the cover to the basin. Do not over-torque the cover bolts.

1

Little Giant Pump Company

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiant.com

[email protected]

CS-SS

Crawl Space Sump System

Système de puisard pour 

vide sanitaire

Sistema de sumidero para

espacio de servicio

Instruction sheet, grommets

and hardware in polybag

Feuillet d’instructions, œillets et

ferrures dans le sac de polyéthylène

Hoja de instrucciones, arandelas y

herrajes en bolsa de polietileno

Connect to a 115V grounded outlet

Brancher à une prise 115 V 

mise à la terre

Conectar a toma de corriente de

115V puesta a tierra

Large gravel backfill

Remblai de gros gravier

Relleno grande de grava

Earth • Terre • Tierra

CS-SS Pre-Packaged Basin Assembly

Assemblage de bassin préemballé

Ensamblado de la cubeta preembalado

14940655

Typical Installation

Installation typique

Instalación típica

Cover • Couvercle • Tapa
14940654

Coiled flex tubing
Flexible en serpentin
Tubería flexible en espiral
599301

6E-CIA-SFS
506701

Check Valve
Clapet anti-retour
Válvula de retención
577130

Perforated Basin
Bassin perforé
Cubeta perforada
14940653

Crawl Space Area
Vide sanitaire
Área del espacio de servicio

Floor Joist
Solive de plancher
Vigueta de soporte 
del piso

Stem Wall
Mur de fondation
Cimiento en forma 
de T invertida

Check Valve
Clapet anti-retour
Válvula de retención

Footing
Semelle
Zócalo

Frost Line
Profondeur de gel
Profundidad de la 
altura de helada

Slope discharge pipe away from 
foundation and below frost line
 

Donner une pente au conduit 

 

d’évacuation dans la direction opposée 

 

à la fondation et sous la profondeur de gel

 

            Incline la tubería de descarga, 

 

            alejándola de la base y por debajo 

 

            de la profundidad de la altura de helada.

PVC Pipe • Conduit de 

PVC • Tubería de PVC

Содержание CS-SS

Страница 1: ...the pump in and run water into the basin until the pump switches on If the pump does not switch on refer to trouble shooting information in the instruction sheet for the pump Secure the cover to the basin Do not over torque the cover bolts 1 Little Giant Pump Company P O Box 12010 Oklahoma City OK 73157 2010 405 947 2511 Fax 405 947 8720 www LittleGiant com customerservice lgpc com CS SS Crawl Spa...

Страница 2: ...CTIVES DE SÉCURITÉ LEA TODAS LAS INSTRUCCIONES GENERALES Y DE INSTA LACIÓN COMPLETAMENTE EL NO SEGUIR LAS INSTRUC CIONES PODRÍA CAUSAR SERIAS LESIONES CORPORALES Y O DAÑOS A LA PROPIEDAD CUIDADO Verifique que la fuente de energía sea adecuada para manejar los requisitos de voltaje de la bomba como se indica en la placa de identificación de la misma Asegúrese de que el circuito de suministro eléctr...

Страница 3: ...al damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country The National Electric Code in the USA and similar codes in other countries require a Ground Fault Circuit Interrupter GFCI to be installed in the branch circuit supplying fountain equipment rate...

Страница 4: ...de los detalles del problema para que la fábrica disponga de las acciones necesarias y resuelva el reclamo de la garantía DESAUTORIZACION LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQUIER OTRA GARANTIA EXPRESA CUALQUIER GARANTIA IMPLICADA INCLUYENDO PERO NO LIMITADO A CUALQUIER GARANTIA IMPLICADA DE COMER CIALIZACION O APTITUD PARA PROPOSITO PARTICULAR EN LA MEDIDA EN QUE SE PUE...

Отзывы: