Control Cavity 9–5
Meter Setting
Wire Combination
Good Motor Resistance
Bad Motor Resistance
200
Black/Red
1.5 – 2.5 ohms
Infinity
200
Black/Gray
1.5 – 2.5 ohms
Infinity
200
Yellow/Blue
1.5 – 2.5 ohms
Infinity
200
Yellow/Black
Infinity
Any reading
2000K or 2M
Ground/All motor leads
Infinity
Any reading; possibly wa-
ter in motor. Dry windings
and retest.
Megger
Ground/All motor leads
500M or higher
Below 500M
Motor Field Winding Resistance
Table 9–1
Motor Windings Test
Perform motor winding resistance checks per the following charts to verify motor condition.
Note:
While all of the wires are disconnected between the control bracket and the power cable,
replace the two O-rings on the motor casting before rewiring the controls. Use Molycote 55
grease on the motor housing and the motor head O-rings. Use silicone grease on all other
O-rings.
Wire Color
Function
Black
Run/Start windings and internal thermal protector
Blue
Run windings
Gray
Run windings
Yellow
Run windings
Red
Run windings
Orange
Jumper lead (120V only)
Table 9–2
Motor Wire Functions
Содержание Extreme Series
Страница 1: ...Service Manual E One Extreme Grinder Pumps 240V 60 Hz Hardwired Controls...
Страница 2: ......
Страница 32: ...Pump End 5 8 Figure 5 9a D Series Pump Exploded View...
Страница 33: ...Pump End 5 9 Figure 5 9b W Series Pump Exploded View...
Страница 34: ...Pump End 5 10 Figure 5 9c Gatorgrinder GH Series Pump Exploded View...
Страница 35: ...Pump End 5 11 Figure 5 9d IH091 Pump Exploded View...
Страница 36: ...Pump End 5 12...
Страница 58: ...Level Sensor 8 10 Figure 8 35 Level Sensor Assembly Exploded View all hardwired pumps...
Страница 70: ...Mechanical Seal Assembly 11 2...
Страница 75: ......