Level Sensor 8–5
1.
If the barbed fitting or liquid tight cord grip is being replaced, put a fine bead of
Loctite 598 on the threads before installing them into the assembly.
2.
Using Dow 111 grease, lubricate the O-rings on the new switches (Fig. 8-16) and
install them (On/Off switch in the Equalizer barbed fitting side and the Alarm switch
in the cable entry side). Install a new molded radial seal on the On/Off side and
lubricate the exposed surface (Fig. 8-17).
3.
Feed the cable through the cord grip (Fig. 8-18), reinstall the compression nut and
tighten (Fig. 8-19).
4.
Install new flag terminals (PT# 7115) and reconnect the wires: (On/Off) Red to Pin 1
and Brown to Pin 3; (Alarm) Yellow to Pin 1 and Blue to Pin 3.
Note:
Flag terminals
must be crimped using a flag terminal crimper (PT# NA0237P01 or equivalent).
Reinstall the switch retainers.
Figure 8-14
Figure 8-15
Figure 8-16
Figure 8-17
Figure 8-18
Figure 8-19