![Ditch Witch JT5 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/ditch-witch/jt5/jt5_operators-manual_2510009095.webp)
Systems and Equipment - 94
JT5 Operator’s Manual
Electric Strike System
CMW
®
Use Electric Strike Simulator
Use the Electric Strike Simulator (p/n 259-506) to test voltage and current sensors on ESID. If readings are
less than indicated here, replace 9V battery in simulator and retest.
Current Test
To test for current at normal levels:
1.
Thread one lead wire through current transformer.
2.
Clip ends of lead wires together to make one loop.
3.
Move simulator switch to "current" and press test button.
4.
Watch screen and lights above display on strike system.
•
Three or four lights should turn on.
•
Current "A" should show 30-50% in display.
EV2 code displays and
voltage problem indicator is
on
Improper connections with
control module
Check cable connection on control
module
Defective voltage limiter
Have voltage limiter checked or
replaced
Defective control module
Have control module checked or
replaced
Problem
Possible cause
Possible solution
Содержание JT5
Страница 1: ...JT5 Issue 3 0 Original Instruction Operator s Manual CMW 053 2380...
Страница 7: ...Overview 6 JT5 Operator s Manual CMW...
Страница 21: ...Safety 20 JT5 Operator s Manual Machine Safety Alerts CMW...
Страница 58: ...JT5 Operator s Manual Drive 57 CMW Drive Chapter Contents Start Unit 58 Steer Unit 58 Shut Down Unit 59...
Страница 61: ...Drive 60 JT5 Operator s Manual Shut Down Unit CMW...
Страница 85: ...Conduct a Bore 84 JT5 Operator s Manual Remove Pullback Device CMW...
Страница 119: ...Complete the Job 118 JT5 Operator s Manual Stow Tools CMW...
Страница 149: ...Specifications 148 JT5 Operator s Manual CMW...
Страница 152: ......
Страница 153: ......
Страница 154: ...JT5 Operator s Manual Service Record 153 CMW Service Record Service Performed Date Hours...
Страница 155: ...CMW Service Record 154 JT5 Operator s Manual Service Performed Date Hours...