smartDEN Opener
User Manual
24 Apr 2018
- 41 -
7. Default settings
7.1.
Table with default settings
The
smartDEN Opener
module is shipped with default (factory) settings shown in the table
below. The default settings can be reloaded, if necessary following the steps in
chapter 7.2
.
Table 7.1.
Default settings
Settings group
Parameter
(according Web pages)
Value
General Settings
Device Name
smartDEN Opener
Device Location
location
Username
admin
Password
admin
Network Settings
Mode
AP
SSID
SmartDEN_Opener_XXXXXX
Password
Disabled (Open Network)
Channel
AUTO
DHCP
Enabled
IP Address
192.168.4.1
Subnet Mask
255.255.255.0
Output Power
20.5 dBm
HTTP & XML
Access
HTTP Port
80
Access IP Address
0.0.0.0
Access Mask
0.0.0.0
Session Timeout, min
5
Enable Admin XML Access
Yes
Enable Guest XML Access
No
MQTT Access
MQTT Broker
iot.eclipse.org
MQTT Port
1883
Enable Admin MQTT Access
Yes
Enable Guest MQTT Access
No
Sender Email Address
Sender Email Password
xxxxxx
SMTP Server
162.241.231.158
SMTP Port
587
Users
Admin Password
admin
Admin Enabled
Yes
Guest Password
guest
Guest Enabled
No
NTP
NTP Server
pool.ntp.org
NTP Port
123
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...