smartDEN Opener
User Manual
24 Apr 2018
- 55 -
Figure 10.12.
Close on Deactivated DI Protection Sensor
options behavior
When using
DI Protection Sensor
for proper working be sure that nothing will DISABLE
its alarm (for example week schedule could make it malfunction if DISABLE event
occurs).
Current Protection Limit
- This value is used when Main Controlled Device is
CLOSING
.
If the current units become higher than this value, the Main Controlled Device will start
OPENING
. If this parameter is 1024, the current protection is disabled. If current protection
is desired, make sure that this value is more than
Max Current Read Value
to prevent
unwanted
OPENING
during
CLOSING
. If Main Controlled Device is
OPENED
by
Current