6.13.2.
Via RF remote
1. Press the two buttons from the RF remote at the same time. The
smartDEN Opener
status
led will start flashing (for about 5 sec);
2. Wait until the status led stop flashing;
3. Release the buttons;
4. Pres RF remote "Open" button so the Main Controlled Device goes to
OPENED
position;
5. Release the RF remote "Open" button;
6. Press the RF remote "Close" button;
7. Wait until the Main Controlled Device goes to
CLOSED
position. The status led will blink
with period 0.5 sec during this time;
8. Release the RF remote "Close" button. Now the
Open/Close time
is stored in memory;
9. Press the both RF buttons together. The
smartDEN Opener
status led will become flashing
for about 7 sec;
10. Wait until the status led stop flashing;
11. Release the buttons;
12. The
smartDEN Opener
is rebooted with the new opening/closing time.
Figure 6.36.
Open/Close Time programming via RF Remote Controller
6.14. Setting the protections
6.14.1.
Setting the primary current protection
smartDEN Opener
provides current protection for Main Controlled Device's motor. It measures
the current through Main Controlled Device's motor and if the measured current (consumed by the
motor) is more than certain level, the Main Controlled Device stop closing and start opening
almost immediately automatically. Such kind of protection is very useful in cases where the Main
Controlled Device (garage door, barrier) may hits an object (car for example) and in that moment
the motor current consumption is increased. The protection parameters can be set from the web
server, in page for the Main Controlled Device:
Current Protection Limit, units
- this is the level of measured current which triggers
opening the Main Controlled Device. If the current units become higher than this value, the
Main Controlled Device will start
OPENING
. It is in ADC raw units. If this parameter is 1024,
the current protection is disabled;
Real Time Current Sensor Value
,
units
- when closing the Main Controlled Device
this
parameter show the current motor consumption for reference. It is in ADC raw units;
Max Current Sensor Value
,
units
- the maximum measured current while closing the Main
Controlled Device
.
It is in ADC raw units;
Figure 6.37.
Current protection options (Main Controlled Device page)
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...