smartDEN Opener
User Manual
24 Apr 2018
- 73 -
when LOW ALARM event is generated and turns off after time specified in Relay 1
Time
parameter.
10.6.3.
Temperature Input
Figure 10.26.
Temperature Input page
smartDEN Opener
provides one temperature input for Dallas One Wire Temperature Sensor
(for example DS18S20):
Description
- allows naming the temperature input. There are 10 allowed symbols reserved
for description (see
Appendix 3
);
Dimension
- this is the dimension of measured temperature. There are two choices -
Celsius (
o
C) and Fahrenheit (
o
F);
Low Alarm
- sets the value on which LOW ALARM event will be generated. LOW ALARM
event is generated when the temperature has been higher than
High Alarm
parameter
value and then falls below
Low Alarm
parameter value;
High Alarm
- sets the value on which HIGH ALARM event will be generated. HIGH ALARM
event is generated when the temperature has been lower than
Low Alarm
parameter value
and then exceeds
High Alarm
parameter value;
Enable Alarm
- if this option is checked alarms will be generated for the temperature input;
Send notification On
- this parameter allows sending notifications on specified alarm.
There are four choices:
o
Never
-
smartDEN Opener
will not send any notifications about temperature input;
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...