smartDEN Opener
User Manual
24 Apr 2018
- 74 -
o
Low Alarm
- controller will send notifications only on LOW ALARM event generated by
temperature input;
o
High Alarm
- controller will send notifications only on HIGH ALARM event generated by
temperature input;
o
Any Alarm
- will send notifications on both LOW and HIGH ALARM events;
Send Email On
- this parameter allows sending emails on specified alarm. There are four
identical to notifications choices:
o
Never
-
smartDEN Opener
will not send any notifications about temperature input;
o
Low Alarm
- controller will send emails only on LOW ALARM event generated by
temperature input;
o
High Alarm
- controller will send emails only on HIGH ALARM event generated by
temperature input;
o
Any Alarm
- will send emails on both LOW and HIGH ALARM events;
Log On
- this parameter allows writing to events log only on specified alarm. There are
same choices as emails and notifications:
o
Never
-
smartDEN Opener
will not write log messages about temperature input;
o
Low Alarm
- controller will write log messages only on LOW ALARM event generated by
temperature input;
o
High Alarm
- controller will write log messages only on HIGH ALARM event generated
by temperature input;
o
Any Alarm
- will write log messages on both LOW and HIGH ALARM events;
Controls
- This parameter specifies which output is controlled by the temperature input.
There are four choices:
o
Nothing
- this analog input will not control any output. If some of the previous settings
are set it will be used for monitoring some process;
o
Relay 1
- the temperature input will control Relay 1;
o
Relay 2
- the temperature input will control Relay 2;
o
Main
- the temperature input will control Main Controlled Device;
Control Mode
(
Controls
is set to "Relay 1" or "Relay 2"):
o
Normal
- in this mode the selected relay will turn on when temperature input generates
HIGH ALARM event and will turn off when LOW ALARM event is generated;
o
Inversed
- in this mode the selected relay will turn on when temperature input generates
LOW ALARM event and will turn off when HIGH ALARM event is generated;
Control Mode
(
Controls
is set to "Main"):
o
Open
- in this mode Main Controlled Device will start
OPENING
on HIGH ALARM event
if not
OPENED
;
o
Close
- in this mode Main Controlled Device will start
CLOSING
on LOW ALARM event
if not
CLOSED
;
o
Open/Close
- in this mode Main Controlled Device will start
CLOSING
on LOW ALARM
event and will start
OPENING
on HIGH ALARM event;
o
Close/Open
- in this mode Main Controlled Device will start
OPENING
on LOW ALARM
event and will start
CLOSING
on HIGH ALARM event;
Save
- before leaving this tab or page click this button to changes take effect.
Next figures illustrate
Control Mode
parameter examples. The principle of control mode is the
same as Analog Input. That's why the examples given below are same as Analog Input's.
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...