smartDEN Opener
User Manual
24 Apr 2018
- 63 -
On the figure above, Digital Input 1 (named "DI1") controls Relay 1 on "Any Alarm" (LOW
ALARM EVENT and HIGH ALARM event respectively). First three graphics are captured with
Relay 1 working in "Normal"
Relay Switch Mode
.
As shown on the graphics DI1 first makes transition from HIGH to LOW level and generates
LOW ALARM EVENT. In "Normal"
Control Mode
if the Relay 1 was turned on then it turns off. In
"Inversed"
Control Mode
if the Relay 1 was turned off then it turns on. In "Toggle"
Control Mode
if the Relay 1 was turned off then it turns on. On this point an email is sent.
The next transition generates HIGH ALARM. In "Normal"
Control Mode
if the Relay 1 was
turned off then it turns on. In "Inversed"
Control Mode
if the Relay 1 was turned on then it turns
off. In "Toggle"
Control Mode
if the Relay 1 was turned on then it turns off. On this point a log
message is written to events log.
The last transition on generates LOW ALARM EVENT again. The states are identical to the first
LOW ALARM EVENT.
Last two graphics show "Toggle" and "Normal"
Control Mode
but with Relay 1 configured to
work in "Timer On" and "Timer Off"
Relay Switch Mode
. As shown on graphics, Relay 1 turns on
or off automatically after time specified by the Relay 1
Time
parameter.
The next examples are about controlling Main Controlled Device from digital input.
Figure 10.19.
Digital Input controlling Main Controlled Device settings
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...