o
Turn On When Closed
- this option will turn on the relay when the Main Controlled
Device is
CLOSED
. Suitable for heaters in the winter;
o
Turn Off When Closed
- this option will turn on the relay when the Main Controlled
Device is
CLOSED
. Suitable for heaters in the lamps;
Attach DI Protection Sensor
-
you can "attach" a digital input which will prevent the door
from closing when an object is detected and auto-close when the object is gone. For proper
use of this parameter it is needed to be a digital input with constant output (not pulse). For
example barrier sensor mounted under the door/barrier is a proper choice:
o
No sensor
- will not "attach" a Digital Input to the Main Controlled Device;
o
Low Level
- will "attach" the selected Digital Input and will be
ACTIVATED
when the
level on the selected Digital Input is LOW;
High Level
- will "attach" the selected Digital Input and will be
ACTIVATED
when the
level on the selected Digital Input is HIGH;
Figure 10.10
. DI Protection Sensor Levels
Close on Deactivated DI Protection Sensor
- this parameter is used to close the Main
Controlled Device by the DI protection sensor. When object is entering in the zone of
sensor, it is called
ACTIVATED
state and when leaving it is
DEACTIVATED
state. The
condition for
CLOSING
is that DI protection sensor must be
ACTIVATED
first and then
DEACTIVATED
:
o
Never
- the Main Controlled Device will never be closed by DI protection sensor;
o
On Close Command
- the Main Controlled Device will be closed only if
CLOSE
command is received during
OPENING
or in
OPENED
state and only if the DI protection
sensor is
DEACTIVATED
in the way described above;
o
Always
- the Main Controlled Device will be closed every time when the DI Protection
sensor is
DEACTIVATED
;
Figure 10.11
.
Close on Deactivated DI Protection Sensor
options
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...