smartDEN Opener
User Manual
24 Apr 2018
- 44 -
9. Main Controlled Device
smartDEN Opener
provides output to control load driven by AC/DC motor. This load is called
Main Controlled Device -garage door, blind, awning, window, barrier etc. Main Controlled Device
has five states:
9.1. OPENING
OPENING
is the state which the Main Controlled Device was in
STOPPED
or
CLOSED
state
and
OPEN
command is received (from RF Remote Controlled, web server, etc.). Then voltage is
provided between COM and OPEN terminals on motor output terminal.
Open
/
Close Time
starts
decrementing until time elapse. When time elapse motor driven load is stopped and no voltage is
provided on motor output terminal. Main Controlled Device is now in
OPENED
state.
If during
OPENING
state
OPEN
command is received Main Controlled Device will continue
OPENING
.
If during
OPENING
state
CLOSE
command is received Main Controlled Device will go to
STOPPED
state.
If during
OPENING
state
STOP
command is received Main Controlled Device will go to
STOPPED
state.
9.2. CLOSING
CLOSING
is the state which the Main Controlled Device was in
STOPPED
or
OPENED
state
and
CLOSE
command is received (from RF remote, web server, etc.). Then voltage is provided
between COM and CLOSE terminals on motor output terminal.
Open
/
Close Time
starts
decrementing until time elapse. When time elapse motor driven load is stopped and no voltage is
provided on motor output terminal. Main Controlled Device is now in
CLOSED
state.
If during
CLOSING
state
CLOSE
command is received Main Controlled Device will continue
CLOSING
.
If during
CLOSING
state
OPEN
command is received Main Controlled Device will go to
STOPPED
state.
If during
CLOSING
state
STOP
command is received Main Controlled Device will go to
STOPPED
state.
9.3. OPENED
OPENED
is the state which the Main Controlled Device was reached one of its end position.
Then no voltage is provided on motor output terminal.
If during
OPENED
state
CLOSE
command is received Main Controlled Device will start
CLOSING
.
If during
OPENED
state
OPEN
command is received Main Controlled Device will take no
action.
If during
OPENED
state
STOP
command is received Main Controlled Device will go to
STOPPED
state.
9.4. CLOSED
CLOSED
is the state which the Main Controlled Device was reached one of its end position.
Then no voltage is provided on motor output terminal.
If during
CLOSED
state
OPEN
command is received Main Controlled Device will start
OPENING
.
Содержание smartDEN Opener
Страница 15: ...smartDEN Opener User Manual 24 Apr 2018 15 Figure 5 2 Distribution box version overview...
Страница 62: ...smartDEN Opener User Manual 24 Apr 2018 62 Figure 10 18 Digital input controlling relay examples...
Страница 80: ...smartDEN Opener User Manual 24 Apr 2018 80 10 7 General Settings Figure 10 32 General Settings page...
Страница 107: ...smartDEN Opener User Manual 24 Apr 2018 107 12 2 9 MQTT command reply Figure 12 2 MQTT successful response...
Страница 114: ...smartDEN Opener User Manual 24 Apr 2018 114 Figure 16 4 Relays Tab Figure 16 5 Main Controlled Device s modes...
Страница 116: ...smartDEN Opener User Manual 24 Apr 2018 116 Figure 16 8 GPS outside mode notification...