Manual initialisation
1.
Disconnect from mains and wait until the display
turns off.
2.
2a
Press [Status] - [Main Menu] - [OK] at
the same time while power up for LCP
102, Graphical Display
2b
Press [Menu] while power up for LCP
101, Numerical Display
3.
Release the keys after 5 s.
4.
The frequency converter is now programmed
according to default settings.
This procedure initialises all except:
NOTE
A manual initialisation also resets serial communication, RFI
filter settings (
) and fault log settings.
How to Programme
VLT
®
AutomationDrive Programmming Guide
22
MG33ME02 - VLT
®
is a registered Danfoss trademark
2
2