8-05 End-of-Timeout Function
Option:
Function:
[1]
*
Resume set-
up
Resumes the set-up active before the time-
out.
8-06 Reset Control Word Timeout
This parameter is active only when
[0] Hold set-up
has been
selected in
Option:
Function:
[0]
*
Do not reset Retains the set-up specified in
, following a control
word time-out.
[1]
Do reset
Returns the frequency converter to the
original set-up following a control word time-
out. The frequency converter performs the
reset and then immediately reverts to the
[0]
Do not reset
setting
8-08 Readout Filtering
If the speed feedback value readouts on fieldbus are fluctuating,
this function is used. Select filtered if the function is required. A
power-cycle is required for changes to take effect.
Option:
Function:
[0]
*
Motor Data Std-
Filt.
Select
[0]
for normal bus
readouts.
[1]
Motor Data LP-
Filter
Select
[1]
for filtered bus
readouts of the following
parameters:
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-14 Motor Current
16-16 Torque [Nm]
16-17 Speed [RPM]
16-22 Torque [%]
16-25 Torque [Nm] High
3.10.2 8-1* Ctrl. Word Settings
8-10 Control Word Profile
Select the interpretation of the control and status words
corresponding to the installed fieldbus. Only the selections valid
for the fieldbus installed in slot A will be visible in the LCP
display.
For guidelines in selection of
[0] FC profile
and
[1] PROFIdrive
profile
please refer to the
Serial communication via RS-485
Interface
section in the Design Guide.
For additional guidelines in the selection of
[1] PROFIdrive profile
,
please refer to the Operating Instructions for the installed
fieldbus.
Option:
Function:
[0]
*
FC profile
[1]
PROFIdrive profile
8-10 Control Word Profile
Select the interpretation of the control and status words
corresponding to the installed fieldbus. Only the selections valid
for the fieldbus installed in slot A will be visible in the LCP
display.
For guidelines in selection of
[0] FC profile
and
[1] PROFIdrive
profile
please refer to the
Serial communication via RS-485
Interface
section in the Design Guide.
For additional guidelines in the selection of
[1] PROFIdrive profile
,
please refer to the Operating Instructions for the installed
fieldbus.
Option:
Function:
[5]
ODVA
[7]
CANopen DSP 402
[8]
MCO
8-13 Configurable Status Word STW
Option:
Function:
[0]
No function
The input is always low.
[1]
*
Profile Default
Depended on the profile set in
8-10 Control Profile
.
[2]
Alarm 68 Only
The input goes high whenever
Alarm 68 is active and goes low
whenever no alarm 68 is actived
[3]
Trip excl Alarm 68
[10] T18 DI status
[11] T19 DI status
[12] T27 DI status
[13] T29 DI status
[14] T32 DI status
[15] T33 DI status
[16] T37 DI status
The input goes high whenever T37
has 0 V and goes low whenever
T37 has 24 V
[21] Thermal warning
[30] Brake fault (IGBT)
[40] Out of ref range
[41] Load throttle active
[60] Comparator 0
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
[65] Comparator 5
[70] Logic Rule 0
[71] Logic Rule 1
[72] Logic Rule 2
[73] Logic Rule 3
[74] Logic Rule 4
[75] Logic Rule 5
[80] SL digital out A
[81] SL digital out B
[82] SL digital out C
[83] SL digital out D
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
106
MG33ME02 - VLT
®
is a registered Danfoss trademark
3
3
Содержание VLT AutomationDrive FC 300 Series
Страница 1: ...MAKING MODERN LIVING POSSIBLE Programming Guide VLT AutomationDrive...
Страница 210: ...www danfoss com drives MG33ME02 130R0334 MG33ME02 Rev 2012 02 20...
Страница 211: ......