13-10 Comparator Operand
Array [6]
Option:
Function:
[13]
Analog input
AI54
[13] Analog input AI54
Expressed as a
percentage.
[14]
Analog input
AIFB10
[14] Analog input AIFB10
[V]. AIFB10 is
internal 10 V supply.
[15]
Analog input
AIS24V
[15] Analog input AIS24V
[V] Analog
input AICCT [17] [°]. AIS24V is switch
mode power supply: SMPS 24V.
[17]
Analog input
AICCT
[17] Analog input AICCT
[°]. AICCT is
control card temperature.
[18]
Pulse input FI29
[18] Pulse input FI29
Expressed as a
percentage.
[19]
Pulse input FI33
[19] Pulse input FI33
Expressed as a
percentage.
[20]
Alarm number
[20] Alarm number
The error number.
[21]
Warning number
[22]
Analog input
x30 11
[23]
Analog input
x30 12
[30]
Counter A
[30] Counter A
Number of counts
[31]
Counter B
[31] Counter B
Number of counts
[50]
FALSE
[50] False
Enters the fixed value of false
in the comparator.
[51]
TRUE
[51] True
Enters the fixed value of true
in the comparator.
[52]
Control ready
[52] Control ready
The control board
receives supply voltage
[53]
Drive ready
[53] Drive ready
The frequency converter
is ready for operation and applies a
supply signal on the control board.
[54]
Running
[54] Running
The motor is running.
[55]
Reversing
[55] Reversing
The output is high when
the frequency converter is running
counter clockwise (the logical product of
the status bits “running” AND “reverse”)
[56]
In range
[56] In range
The motor is running
within the programmed current and
speed ranges set in
to
.
[60]
On reference
[60] On reference
The motor is running
on reference.
[61]
Below reference,
low
[61] Below reference, low
The motor is
running below the value given in
13-10 Comparator Operand
Array [6]
Option:
Function:
[62]
Above ref, high
[62] Above reference, high
The motor is
running above the value given in
[65]
Torque limit
[65] Torque limit
The torque limit, set in
or
4-17 Torque Limit Generator Mode
, has
been exceeded.
[66]
Current limit
[66] Current limit
The motor current
limit, set in
, has been
exceeded.
[67]
Out of current
range
[67] Out of current range
The motor
current is outside the range set in
.
[68]
Below I low
[68] Below I low
The motor current is
lower than set in
[69]
Above I high
[69] Above I high
The motor current is
higher than set in
[70]
Out of speed
range
[70] Out of speed range
The speed is
outside the range set in
and
.
[71]
Below speed low
[71] Below speed low
The output speed
is lower than the setting in
.
[72]
Above speed
high
[72] Above speed high
The output speed
is higher than the setting in
.
[75]
Out of feedb.
range
[75] Out of feedb. Range
The feedback is
outside the range set in
and
.
[76]
Below feedb.
low
[76] Below feedb. Low
The feedback is
below the limit set in
.
[77]
Above feedb.
high
[77] Above feedb. High
The feedback is
above the limit set in
.
[80]
Thermal warning
[80] Thermal warning
The thermal
warning turns on when the temperature
exceeds the limit in the motor, the
frequency converter, the brake resistor
or thermistor.
[82]
Mains out of
range
[82] Mains out of range
The mains
voltage is outside the specified voltage
range.
[85]
Warning
[85] Warning
A warning is active.
[86]
Alarm (trip)
[86] Alarm (trip)
A (trip) alarm is active.
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide