4.1.8 5-** Digital In/Out
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
5-0* Digital I/O mode
5-00
Digital I/O Mode
[0] PNP
All set-ups
FALSE
-
Uint8
5-01
Terminal 27 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-02
Terminal 29 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
null
All set-ups
TRUE
-
Uint8
5-11
Terminal 19 Digital Input
null
All set-ups
TRUE
-
Uint8
5-12
Terminal 27 Digital Input
null
All set-ups
TRUE
-
Uint8
5-13
Terminal 29 Digital Input
null
All set-ups
TRUE
-
Uint8
5-14
Terminal 32 Digital Input
null
All set-ups
TRUE
-
Uint8
5-15
Terminal 33 Digital Input
null
All set-ups
TRUE
-
Uint8
5-19
Terminal 37 Safe Stop
[1] Safe Stop Alarm
1 set-up
TRUE
-
Uint8
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
null
All set-ups
TRUE
-
Uint8
5-31
Terminal 29 Digital Output
null
All set-ups
TRUE
-
Uint8
5-4* Relays
5-40
Function Relay
null
All set-ups
TRUE
-
Uint8
5-41
On Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-42
Off Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-5* Pulse Input
5-50
Term. 29 Low Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-51
Term. 29 High Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-52
Term. 29 Low Ref./Feedb. Value
0.000 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
5-53
Term. 29 High Ref./Feedb. Value
App.Dependent
All set-ups
TRUE
-3
Int32
5-54
Pulse Filter Time Constant #29
100 ms
All set-ups
FALSE
-3
Uint16
5-55
Term. 33 Low Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-56
Term. 33 High Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-57
Term. 33 Low Ref./Feedb. Value
0.000 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
5-58
Term. 33 High Ref./Feedb. Value
App.Dependent
All set-ups
TRUE
-3
Int32
5-59
Pulse Filter Time Constant #33
100 ms
All set-ups
FALSE
-3
Uint16
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
null
All set-ups
TRUE
-
Uint8
5-62
Pulse Output Max Freq #27
App.Dependent
All set-ups
TRUE
0
Uint32
5-63
Terminal 29 Pulse Output Variable
null
All set-ups
TRUE
-
Uint8
5-65
Pulse Output Max Freq #29
App.Dependent
All set-ups
TRUE
0
Uint32
5-7* 24V Encoder Input
5-70
Term 32/33 Pulses per Revolution
1024 N/A
All set-ups
FALSE
0
Uint16
5-71
Term 32/33 Encoder Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
5-8* I/O Options
5-80
AHF Cap Reconnect Delay
25 s
2 set-ups
TRUE
0
Uint16
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
0 N/A
All set-ups
TRUE
0
Uint32
5-93
Pulse Out #27 Bus Control
0.00%
All set-ups
TRUE
-2
N2
5-94
Pulse Out #27 Timeout Preset
0.00%
1 set-up
TRUE
-2
Uint16
5-95
Pulse Out #29 Bus Control
0.00%
All set-ups
TRUE
-2
N2
5-96
Pulse Out #29 Timeout Preset
0.00%
1 set-up
TRUE
-2
Uint16
Table 4.11
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark
171
4
4